設計 · 木構造

軸圧縮と曲げの組合せによる柱安定性の確認

  • タイプ:検証
  • バージョン1
  • 2026/11/10にレビュー済み

EN 1995-1-1 6.3.2 式6.23による軸圧縮と曲げの組合せに対する部材安定性検証: η = σc,0,d / (kc,y × fc,0,d) + σm,y,d / fm,y,d + km × (σm,z,d / fm,z,d) ≤ 1.0。

η=σc,0,d/(kc,y⋅fc,0,d)+σm,y,d/fm,y,d+km⋅(σm,z,d/fm,z,d)\displaystyle \eta = \sigma _{\mathrm{c},0,\mathrm{d}} / (k_{\mathrm{c},y} \cdot f_{\mathrm{c},0,\mathrm{d}}) + \sigma _{m,y,\mathrm{d}} / f_{m,y,\mathrm{d}} + k_{m} \cdot (\sigma _{m,z,\mathrm{d}} / f_{m,z,\mathrm{d}})
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

kcy

Formula and quantities

SymbolNameUnitNote
σc,0,d\displaystyle \sigma_{\mathrm{c},0,\mathrm{d}}繊維方向圧縮設計応力度N/m²
kc,y\displaystyle k_{\mathrm{c},y}y軸回りの座屈低減係数1
fc,0,d\displaystyle f_{\mathrm{c},0,\mathrm{d}}繊維方向圧縮設計強度N/m²
σm,y,d\displaystyle \sigma_{m,y,\mathrm{d}}y軸回りの設計曲げ応力度N/m²
fm,y,d\displaystyle f_{m,y,\mathrm{d}}y軸回りの設計曲げ強度N/m²
km\displaystyle k_{m}断面係数k_m1
σm,z,d\displaystyle \sigma_{m,z,\mathrm{d}}z軸回りの設計曲げ応力度N/m²
fm,z,d\displaystyle f_{m,z,\mathrm{d}}z軸回りの設計曲げ強度N/m²
η\displaystyle \eta梁柱安定性利用率1Result

例題

σc,0,d\displaystyle \sigma_{\mathrm{c},0,\mathrm{d}} = 6,000,000 N/m² · kc,y\displaystyle k_{\mathrm{c},y} = 0.6 · fc,0,d\displaystyle f_{\mathrm{c},0,\mathrm{d}} = 18,000,000 N/m² · σm,y,d\displaystyle \sigma_{m,y,\mathrm{d}} = 3,200,000 N/m² · fm,y,d\displaystyle f_{m,y,\mathrm{d}} = 16,000,000 N/m² · km\displaystyle k_{m} = 0.7 · σm,z,d\displaystyle \sigma_{m,z,\mathrm{d}} = 1,000,000 N/m² · fm,z,d\displaystyle f_{m,z,\mathrm{d}} = 16,000,000 N/m²

η\displaystyle \eta = 0.7993

Standard and source

Result
η\displaystyle \eta in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
η\displaystyle \eta = 0.799306 1= (6,000,000 N/m²) / ((0.6 1) · (18,000,000 N/m²)) + (3,200,000 N/m²) / (16,000,000 N/m²) + (0.7 1) · ((1,000,000 N/m²) / (16,000,000 N/m²))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › 木構造で開始されます。

Miaknows the formula catalog and asks for what is missing.