設計 · 木構造

先穴なし釘の瞬間すべり係数 Kser (EN 1995-1-1)

  • タイプ:特性値
  • バージョン1
  • 2026/11/25にレビュー済み

EN 1995-1-1 表7.1による木材-木材接合における先穴なし釘の1せん断面1本あたりの瞬間すべり係数: Kser = ρm¹.5 · d⁰.8 / 30.

Kser=ρm1.5⋅d0.8/30\displaystyle K_{\mathrm{ser}} = \rho _{m}^1.5 \cdot d^0.8 / 30
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

dKserρm

Formula and quantities

SymbolNameUnitNote
ρm\displaystyle \rho_{m}平均木材密度kg/m³
d\displaystyle d釘径mm
Kser\displaystyle K_{\mathrm{ser}}1せん断面あたりの瞬間すべり係数N/mmResult

例題

ρm\displaystyle \rho_{m} = 420 kg/m³ · d\displaystyle d = 4 mm

Kser\displaystyle K_{\mathrm{ser}} = 869.762 N/mm

Standard and source

Result
Kser\displaystyle K_{\mathrm{ser}} in N/mm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Kser\displaystyle K_{\mathrm{ser}} = 869.762 N/mm= (((420 kg/m³) / 1 [kg/m³])¹.5 · ((4 mm) / 1 [mm])⁰.8 / 30) · 1 [N/mm]