矩形木梁のせん断応力 τd

  • タイプ:作用効果
  • バージョン1
  • 2026/11/9にレビュー済み

矩形木梁の設計せん断応力: τd = 1.5 · Vd / (bef · h)。

τd=1,5⋅Vdbef⋅h\displaystyle \tau_{\mathrm{d}} = \frac{1{,}5 \cdot V_{\mathrm{d}}}{b_{\mathrm{ef}} \cdot h}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

yzbefh

Formula and quantities

SymbolNameUnitNote
Vd\displaystyle V_{\mathrm{d}}設計せん断力kN
bef\displaystyle b_{\mathrm{ef}}せん断用有効幅m
h\displaystyle h断面高さm
τd\displaystyle \tau_{\mathrm{d}}設計せん断応力N/mm²Result

例題

Vd\displaystyle V_{\mathrm{d}} = 25 kN · bef\displaystyle b_{\mathrm{ef}} = 0.0938 m · h\displaystyle h = 0.24 m

τd\displaystyle \tau_{\mathrm{d}} = 1.66578 N/mm² · Source: EN 1995-1-1:2004 式 (6.13)

Scope and standard

EN 1995-1-1 6.1.7項に基づく横せん断力を受ける矩形梁。

Standard
EN 1995-1-1:2004、6.1.7 (1)項、式 (6.13)
Result
τd\displaystyle \tau_{\mathrm{d}} in N/mm²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
τd\displaystyle \tau_{\mathrm{d}} = 1.66578 N/mm²= 1.5 · (25 kN) / ((0.0938 m) · (0.24 m))