構造解析 · 梁

両スパン中央集中荷重時の2径間梁最大たわみ

  • タイプ:作用効果
  • バージョン1

各スパン中央に等しい集中荷重Fが作用する場合の最大たわみ:wmax = F · l³ / (107 · E · I)。

wmax=F⋅l3107⋅E⋅I\displaystyle w_{\mathrm{max}} = \frac{F \cdot l^3}{107 \cdot E \cdot I}
  • General formula, independent of standards
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

FFllwmax

Formula and quantities

SymbolNameUnitNote
F\displaystyle F集中荷重kN
l\displaystyle l支点間距離m
E\displaystyle Eヤング率N/m²
I\displaystyle I断面二次モーメントcm⁴
wmax\displaystyle w_{\mathrm{max}}たわみmResult

例題

F\displaystyle F = 40 kN · l\displaystyle l = 6 m · E\displaystyle E = 210,000,000,000 N/m² · I\displaystyle I = 8,356 cm⁴

wmax\displaystyle w_{\mathrm{max}} = 0.004602 m · Source: 手計算: 40000 · 216 / (107 · 1.75476e7) = 0.0046016 m = 4.602 mm

Scope and standard

2等スパンl、各スパン中央に集中荷重F。

Result
wmax\displaystyle w_{\mathrm{max}} in mm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
wmax\displaystyle w_{\mathrm{max}} = 0.00460164 m= (40 kN) · (6 m)³ / (107 · (210,000,000,000 N/m²) · (8,356 cm⁴))