ACI 318-19 제22.8.3.2절에 따른 재하 콘크리트 면적 A1의 설계지압강도(구속 보정 없음): Bd = φ · 0.85 · fc · A1.

ϕBn=ϕ⋅0.85⋅fc′⋅A1\displaystyle \phi B_{n} = \phi \cdot 0.85 \cdot f'_{\mathrm{c}} \cdot A_{1}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

fc

Formula and quantities

SymbolNameUnitNote
ϕ\displaystyle \phi지압 강도감소계수 (0.65)1
fc\displaystyle f_{\mathrm{c}}콘크리트 설계기준압축강도N/m²
A1\displaystyle A_{1}재하 지압 면적mm²
Bd\displaystyle B_{\mathrm{d}}설계지압강도kNResult

예제

ϕ\displaystyle \phi = 0.65 1 · fc\displaystyle f_{\mathrm{c}} = 28,000,000 N/m² · A1\displaystyle A_{1} = 90,000 mm²

Bd\displaystyle B_{\mathrm{d}} = 1,392.3 kN

Standard and source

Standard
ACI 318-19
Result
Bd\displaystyle B_{\mathrm{d}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Bd\displaystyle B_{\mathrm{d}} = 1,392.3 kN= (0.65 1) · 0.85 · (28,000,000 N/m²) · (90,000 mm²)