设计 · 混凝土

混凝土局压设计承载力 (ACI 318)

  • 类型:验算
  • 版本1
  • 2026/11/15已审核

根据 ACI 318-19 第 22.8.3.2 节,受压混凝土面积 A1 上的局部受压设计承载力(不计约束提高):Bd = φ · 0.85 · fc · A1。

ϕBn=ϕ⋅0.85⋅fc′⋅A1\displaystyle \phi B_{n} = \phi \cdot 0.85 \cdot f'_{\mathrm{c}} \cdot A_{1}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

fc

Formula and quantities

SymbolNameUnitNote
ϕ\displaystyle \phi局部受压强度折减系数(0.65)1
fc\displaystyle f_{\mathrm{c}}混凝土规定抗压强度N/m²
A1\displaystyle A_{1}局部受压面积mm²
Bd\displaystyle B_{\mathrm{d}}局压设计承载力kNResult

实例

ϕ\displaystyle \phi = 0.65 1 · fc\displaystyle f_{\mathrm{c}} = 28,000,000 N/m² · A1\displaystyle A_{1} = 90,000 mm²

Bd\displaystyle B_{\mathrm{d}} = 1,392.3 kN

Standard and source

Standard
ACI 318-19
Result
Bd\displaystyle B_{\mathrm{d}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Bd\displaystyle B_{\mathrm{d}} = 1,392.3 kN= (0.65 1) · 0.85 · (28,000,000 N/m²) · (90,000 mm²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

检索将在 设计 › 混凝土 开始。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.