설계 · 콘크리트
고강도 콘크리트의 유효 강도 계수 η
fck > 50 MPa일 때 등가 직사각형 응력분포의 유효 압축강도를 정의하는 계수 η: η = 1.0 - (fck - 50 MPa) / (200 MPa).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 특성 압축강도 | N/mm² | ||
| 유효 강도 계수 | – | Result |
예제
= 70 N/mm²
= 0.9 · Source: EN 1992-1-1:2004 식 (3.21)
Scope and standard
고강도 콘크리트 50 MPa < f_ck <= 90 MPa (f_ck <= 50 MPa인 경우 η = 1.0).
- Standard
- EN 1992-1-1:2004, 3.1.7 (3) 절, 식 (3.21)
- Result
- (dimensionless)
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
설계 › 콘크리트에서 검색이 시작됩니다.
Miaknows the formula catalog and asks for what is missing.