설계 · 콘크리트
압축영역에 대한 유효 높이 계수 λ
fck > 50 MPa일 때 직사각형 압축대의 유효 깊이를 정의하는 계수 λ: λ = 0.8 - (fck - 50 MPa) / (400 MPa).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 특성 압축강도 | N/mm² | ||
| 유효 압축대 계수 | – | Result |
예제
= 70 N/mm²
= 0.75 · Source: EN 1992-1-1:2004 식 (3.19)
Scope and standard
고강도 콘크리트 50 MPa < f_ck <= 90 MPa (f_ck <= 50 MPa인 경우 λ = 0.8).
- Standard
- EN 1992-1-1:2004, 3.1.7 (3) 절, 식 (3.19)
- Result
- (dimensionless)
Reference to clause and equation, no standard text. The description is written in our own words.