콘크리트 열전도율 하한값 (EN 1992-1-2)
EN 1992-1-2 제3.3.3절 식 (3.2)에 따른 온도(20°C~1200°C) 함수로서의 보통중량 콘크리트 열전도율 하한값: λc = 1.36 - 0.136 · (Θ / 100) + 0.0057 · (Θ / 100)².
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 콘크리트 온도 (20~1200 °C) | 1 | ||
| 콘크리트 열전도율 (W/(m·K)) | 1 | Result |
예제
= 500 1
= 0.8225 1
Standard and source
- Standard
- EN 1992-1-2:2004
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.