설계 · 콘크리트

콘크리트 일방향 전단강도 Vc (ACI 318)

  • 유형: 성질
  • 버전 1
  • 2026. 11. 15.에 검토됨

ACI 318-19 표 22.5.5.1(SI)에 따른 콘크리트의 간략 공칭 일방향 전단강도: Vc = 0.17 · λ · √(fc / MPa) · MPa · bw · d.

Vc=0.17⋅λ⋅fc′⋅bw⋅d\displaystyle V_{\mathrm{c}} = 0.17 \cdot \lambda \cdot \sqrt{f'_{\mathrm{c}}} \cdot b_{w} \cdot d
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

dfc

Formula and quantities

SymbolNameUnitNote
λ\displaystyle \lambda경량콘크리트 계수 (보통콘크리트 1.0)1
fc\displaystyle f_{\mathrm{c}}콘크리트 설계기준압축강도N/m²
bw\displaystyle b_{w}웨브 폭mm
d\displaystyle d유효깊이mm
Vc\displaystyle V_{\mathrm{c}}콘크리트 공칭전단강도kNResult

예제

λ\displaystyle \lambda = 1 1 · fc\displaystyle f_{\mathrm{c}} = 28,000,000 N/m² · bw\displaystyle b_{w} = 300 mm · d\displaystyle d = 500 mm

Vc\displaystyle V_{\mathrm{c}} = 134.93 kN

Standard and source

Standard
ACI 318-19
Result
Vc\displaystyle V_{\mathrm{c}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Vc\displaystyle V_{\mathrm{c}} = 134.933 kN= 0.17 · (1 1) · sqrt((28,000,000 N/m²) / [MPa]) · [MPa] · (300 mm) · (500 mm)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

설계 › 콘크리트에서 검색이 시작됩니다.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.