설계 · 콘크리트
설계 일방향 전단강도 (ACI 318)
ACI 318-19 제22.5.1.1절에 따른 콘크리트와 스터럽 기여분을 합한 전체 설계 일방향 전단강도: Vd = φ · (Vc + Vs).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 전단 강도감소계수 (0.75) | 1 | ||
| 콘크리트 공칭전단강도 | kN | ||
| 스터럽 공칭전단강도 | kN | ||
| 설계 전단강도 | kN | Result |
예제
= 0.75 1 · = 135 kN · = 165 kN
= 225 kN
Standard and source
- Standard
- ACI 318-19
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.