Design · Concrete

Design one-way shear strength (ACI 318)

  • Type: Verification
  • Version 1
  • reviewed on 11/15/2026

Total design one-way shear strength combining concrete and stirrup contributions according to ACI 318-19 Section 22.5.1.1: Vd = φ · (Vc + Vs).

ϕVn=ϕ⋅(Vc+Vs)\displaystyle \phi V_{n} = \phi \cdot (V_{\mathrm{c}} + V_{s})
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Vdφ

Formula and quantities

SymbolNameUnitNote
ϕ\displaystyle \phiStrength reduction factor for shear (0.75)1
Vc\displaystyle V_{\mathrm{c}}Nominal concrete shear strengthkN
Vs\displaystyle V_{s}Nominal stirrup shear strengthkN
Vd\displaystyle V_{\mathrm{d}}Design shear strengthkNResult

Worked example

ϕ\displaystyle \phi = 0.75 1 · Vc\displaystyle V_{\mathrm{c}} = 135 kN · Vs\displaystyle V_{s} = 165 kN

Vd\displaystyle V_{\mathrm{d}} = 225 kN

Standard and source

Standard
ACI 318-19
Result
Vd\displaystyle V_{\mathrm{d}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Vd\displaystyle V_{\mathrm{d}} = 225 kN= (0.75 1) · ((135 kN) + (165 kN))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.