ACI 318-19 제22.5.10.5.3절에 따른 수직 전단철근의 공칭전단강도: Vs = (Av · fyt · d) / s.

Vs=Av⋅fyt⋅ds\displaystyle V_{s} = \frac{A_{v} \cdot f_{yt} \cdot d}{s}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

dfyt

Formula and quantities

SymbolNameUnitNote
Av\displaystyle A_{v}간격 s 내의 전단철근 단면적mm²
fyt\displaystyle f_{yt}횡방향 철근의 설계기준항복강도N/m²
d\displaystyle d유효깊이mm
s\displaystyle s스터럽 중심 간격mm
Vs\displaystyle V_{s}스터럽 공칭전단강도kNResult

예제

Av\displaystyle A_{v} = 157 mm² · fyt\displaystyle f_{yt} = 420,000,000 N/m² · d\displaystyle d = 500 mm · s\displaystyle s = 200 mm

Vs\displaystyle V_{s} = 164.85 kN

Standard and source

Standard
ACI 318-19
Result
Vs\displaystyle V_{s} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Vs\displaystyle V_{s} = 164.85 kN= ((157 mm²) · (420,000,000 N/m²) · (500 mm)) / (200 mm)