設計 · コンクリート構造
せん断補強筋のせん断耐力 Vs (ACI 318)
ACI 318-19 第22.5.10.5.3節による鉛直せん断補強筋の公称せん断耐力: Vs = (Av · fyt · d) / s.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 間隔 s 内のせん断補強筋断面積 | mm² | ||
| せん断補強筋の規格降伏強度 | N/m² | ||
| 有効高さ | mm | ||
| スターラップの中心間隔 | mm | ||
| スターラップの公称せん断耐力 | kN | Result |
例題
= 157 mm² · = 420,000,000 N/m² · = 500 mm · = 200 mm
= 164.85 kN
Standard and source
- Standard
- ACI 318-19
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › コンクリート構造で開始されます。
Miaknows the formula catalog and asks for what is missing.