단면 · 폐쇄 박판 단면

원형 강관(원형 중공 단면, CHS)의 소성 단면 계수

  • 유형: 성질
  • 버전 1

원형 관의 소성 단면계수: Wpl = (d³ - (d - 2 · t)³) / 6.

Wpl=d3−(d−2⋅t)36\displaystyle W_{\mathrm{pl}} = \frac{d^3 - (d - 2 \cdot t)^3}{6}
  • General formula, independent of standards
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

yzdt

Formula and quantities

SymbolNameUnitNote
d\displaystyle d지름mmd\displaystyle d > 0
t\displaystyle t벽 두께mmt\displaystyle t > 0
Wpl\displaystyle W_{\mathrm{pl}}y축에 대한 소성 단면 계수cm³Result

Valid if2⋅t<d\displaystyle 2 \cdot t < d

예제

d\displaystyle d = 100 mm · t\displaystyle t = 5 mm

Wpl\displaystyle W_{\mathrm{pl}} = 45.1667 cm³ · Source: 수기 계산

Scope and standard

원형 강관, t < d / 2.

Result
Wpl\displaystyle W_{\mathrm{pl}} in cm³

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Wpl\displaystyle W_{\mathrm{pl}} = 45.1667 cm³= ((100 mm)³ - ((100 mm) - 2 · (5 mm))³) / 6