설계 · 콘크리트
한계 세장비 λlim
2차 효과를 무시할 수 있는 한계 세장비 기준 (EN 1992-1-1 식 (5.13N)).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 크리프 계수 A = 1 / (1 + 0.2 * phi_ef) | 1 | ||
| 배근 매개변수 B = sqrt(1 + 2 * omega) | 1 | ||
| 모멘트 비 계수 C = 1.7 - r_m | 1 | ||
| 설계 상대 축력 n = N_Ed / (A_c * f_cd) | 1 | ||
| 세장비 한계 | 1 | Result |
예제
= 0.7 1 · = 1.1 1 · = 0.7 1 · = 0.4 1
= 17.0447 1 · Source: EN 1992-1-1:2004 식 (5.13N)
Scope and standard
EN 1992-1-1에 따른 철근 콘크리트 기둥.
- Standard
- EN 1992-1-1:2004, 5.8.3.1 (1) 절, 식 (5.13N)
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
설계 › 콘크리트에서 검색이 시작됩니다.
Miaknows the formula catalog and asks for what is missing.