설계 · 콘크리트
기본 프리스트레스 전달길이 lpt (EN 1992-1-1)
EN 1992-1-1 제8.10.2.2(2)절 식 (8.16)에 따른 프리텐션 긴장재의 기본 전달길이: lpt = α1 · α2 · φ · σpm0 / fbpt.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 긴장 해제 방법 계수 (점진적 1.0, 급격 1.25) | 1 | ||
| 긴장재 단면 계수 (원형 0.25, 7연선 0.19) | 1 | ||
| 긴장재 공칭직경 | mm | ||
| 전달 직후 초기 긴장재 응력 | N/m² | ||
| 일정 전달 부착응력 | N/m² | ||
| 기본 전달길이 | mm | Result |
예제
= 1 · = 0.19 · = 12.5 mm · = 1,300,000,000 N/m² · = 5,760,000 N/m²
= 536.024 mm
Standard and source
- Standard
- EN 1992-1-1:2004
- Result
- in mm
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
설계 › 콘크리트에서 검색이 시작됩니다.
Miaknows the formula catalog and asks for what is missing.