양변 지지 유리판의 휨응력 (EN 16612)
EN 16612 제7.1절에 따른 등분포 표면하중을 받는 마주보는 양변 단순지지 유리판의 최대 선형 휨응력: σ = (3 · q · L²) / (4 · h²).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 등분포 면하중 | N/m² | ||
| 지지변 간 경간길이 | m | ||
| 유리판 두께 | m | ||
| 최대 유리 휨응력 | N/m² | Result |
예제
= 1,500 N/m² · = 1.2 m · = 0.01 m
= 16,200,000 N/m²
Standard and source
- Standard
- EN 16612:2019
- Result
- in MPa
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
설계 › 유리에서 검색이 시작됩니다.
Miaknows the formula catalog and asks for what is missing.