벽체에 작용하는 순풍압

  • 유형: 정의
  • 버전 1

내부 압력을 고려한 외벽 또는 지붕에 작용하는 순풍압.

wnet=we−wi\displaystyle w_{net} = w_{e} - w_{i}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

wnet

Formula and quantities

SymbolNameUnitNote
we\displaystyle w_{e}외부 풍압kN/m²
wi\displaystyle w_{i}내부 풍압kN/m²
wnet\displaystyle w_{net}순풍압kN/m²Result

예제

we\displaystyle w_{e} = 0.68 kN/m² · wi\displaystyle w_{i} = -0.255 kN/m²

wnet\displaystyle w_{net} = 0.935 kN/m² · Source: 수기 계산

Scope and standard

Eurocode 1 (EN 1991-1-4:2005) 5.1절 식 (5.3).

Result
wnet\displaystyle w_{net} in kN/m²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
wnet\displaystyle w_{net} = 0.935 kN/m²= (0.68 kN/m²) - (-0.255 kN/m²)