재료 · 열적 특성

열관류율 (U-값)

  • 유형: 성질
  • 버전 1
  • 2026. 11. 13.에 검토됨

내부 표면 열전달저항 Rsi, 부재 열저항 Rc, 외부 표면 열전달저항 Rse [m²·K/W]로부터 구한 열관류율 U: U = 1 / (Rsi + Rc + Rse).

U=1/(Rsi+Rc+Rse)\displaystyle U = 1 / (R_{si} + R_{\mathrm{c}} + R_{se})
  • General formula, independent of standards
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

U

Formula and quantities

SymbolNameUnitNote
Rsi\displaystyle R_{si}내부 표면 열전달저항 [m^2·K/W]1
Rc\displaystyle R_{\mathrm{c}}부재 열저항 [m^2·K/W]1
Rse\displaystyle R_{se}외부 표면 열전달저항 [m^2·K/W]1
U\displaystyle U열관류율 [W/(m^2·K)]1Result

예제

Rsi\displaystyle R_{si} = 0.13 · Rc\displaystyle R_{\mathrm{c}} = 4.57 · Rse\displaystyle R_{se} = 0.04

U\displaystyle U = 0.211

Standard and source

Result
U\displaystyle U in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

U\displaystyle U = 0.21097 1= 1 / ((0.13 1) + (4.57 1) + (0.04 1))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

재료 › 열적 특성에서 검색이 시작됩니다.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.