설계 · 목재

섬유 방향과 경사진 압축 강도 fc,α,d

  • 유형: 성질
  • 버전 1
  • 2026. 11. 9.에 검토됨

Hankinson 식에 따른 섬유 방향과 α각을 이루는 압축 강도: fc,α,d = fc,0,d / ((fc,0,d / fc,90,d) × sin(α)² + cos(α)²).

fc,α,d=fc,0,dfc,0,dfc,90,d⋅sin⁡(α)2+cos⁡(α)2\displaystyle f_{\mathrm{c},\alpha,\mathrm{d}} = \frac{f_{\mathrm{c},0,\mathrm{d}}}{\frac{f_{\mathrm{c},0,\mathrm{d}}}{f_{\mathrm{c},90,\mathrm{d}}} \cdot \sin(\alpha)^2 + \cos(\alpha)^2}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
fc,0,d\displaystyle f_{\mathrm{c},0,\mathrm{d}}섬유 방향과 평행한 설계 압축 강도N/mm²
fc,90,d\displaystyle f_{\mathrm{c},90,\mathrm{d}}섬유 방향과 수직인 설계 압축 강도N/mm²
α\displaystyle \alpha하중과 섬유 방향 사이의 각도°
fc,α,d\displaystyle f_{\mathrm{c},\alpha,\mathrm{d}}섬유 방향과 경사진 설계 압축 강도N/mm²Result

예제

fc,0,d\displaystyle f_{\mathrm{c},0,\mathrm{d}} = 14 N/mm² · fc,90,d\displaystyle f_{\mathrm{c},90,\mathrm{d}} = 2 N/mm² · α\displaystyle \alpha = 30 °

fc,α,d\displaystyle f_{\mathrm{c},\alpha,\mathrm{d}} = 5.6 N/mm² · Source: EN 1995-1-1:2004 식 (6.16)

Scope and standard

EN 1995-1-1 6.2.2절에 따른 섬유 방향과 경사진 압축을 받는 목재 부재.

Standard
EN 1995-1-1:2004, 6.2.2 (1) 절, 식 (6.16)
Result
fc,α,d\displaystyle f_{\mathrm{c},\alpha,\mathrm{d}} in N/mm²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
fc,α,d\displaystyle f_{\mathrm{c},\alpha,\mathrm{d}} = 5.6 N/mm²= (14 N/mm²) / (((14 N/mm²) / (2 N/mm²)) · sin((30 °))² + cos((30 °))²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

설계 › 목재에서 검색이 시작됩니다.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.