Ontwerp · Beton

Maximale torsieweerstand TRd,max

  • Type: Weerstand
  • Versie 1
  • beoordeeld op 10-11-2026

Maximale ontwerp torsieweerstand bepaald door de capaciteit van de drukstaaf volgens EN 1992-1-1 vergelijking (6.30).

TRd,max=2⋅ν⋅αcw⋅fcd⋅Ak⋅tef⋅sin⁡θ⋅cos⁡θ\displaystyle T_{\mathrm{Rd},\mathrm{max}} = 2 \cdot \nu \cdot \alpha_{cw} \cdot f_{cd} \cdot A_{k} \cdot t_{\mathrm{ef}} \cdot \sin \theta \cdot \cos \theta
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

teffcd

Formula and quantities

SymbolNameUnitNote
ν\displaystyle \nuSterktereductiefactor voor in afschuiving gescheurd beton–
αcw\displaystyle \alpha_{cw}Coëfficiënt voor normale spanningsstaat–
fcd\displaystyle f_{cd}Ontwerpdruksterkte van betonN/mm²
Ak\displaystyle A_{k}Oppervlakte omsloten door de hartlijnen van de verbindingswandenmm²
tef\displaystyle t_{\mathrm{ef}}Effectieve wanddiktemm
sin⁡θ\displaystyle \sin \thetaSinus van de drukstaafhoek–
cos⁡θ\displaystyle \cos \thetaCosinus van de drukstaafhoek–
TRd,max\displaystyle T_{\mathrm{Rd},\mathrm{max}}Maximale torsieweerstandNmResult

Uitgewerkt voorbeeld

ν\displaystyle \nu = 0,528 · αcw\displaystyle \alpha_{cw} = 1 · fcd\displaystyle f_{cd} = 17 N/mm² · Ak\displaystyle A_{k} = 120.000 mm² · tef\displaystyle t_{\mathrm{ef}} = 100 mm · sin⁡θ\displaystyle \sin \theta = 0,7071 · cos⁡θ\displaystyle \cos \theta = 0,7071

TRd,max\displaystyle T_{\mathrm{Rd},\mathrm{max}} = 107.710 Nm · Source: EN 1992-1-1:2004 Vgl. (6.30)

Scope and standard

Betonliggers onderworpen aan torsie volgens EN 1992-1-1.

Standard
EN 1992-1-1:2004, paragraaf 6.3.2 (4), Verg. (6.30)
Result
TRd,max\displaystyle T_{\mathrm{Rd},\mathrm{max}} in kN*m

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
TRd,max\displaystyle T_{\mathrm{Rd},\mathrm{max}} = 107.710 Nm= 2 · 0,528 · 1 · (17 N/mm²) · (120.000 mm²) · (100 mm) · 0,7071 · 0,7071

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

De zoekactie start over Ontwerp › Beton.

Miaknows the formula catalog and asks for what is missing.