Seções transversais · Seções abertas de paredes delgadas

Constante de empenamento Iw de uma seção I

  • Tipo: Propriedade
  • Versão 1

Constante de empenamento de seção I duplamente simétrica: Iw = Iz · (h - tf)² / 4.

Iw=(2⋅tf⋅b3+(h−2⋅tf)⋅tw3)⋅(h−tf)248\displaystyle I_{w} = \frac{(2 \cdot t_{f} \cdot b^3 + (h - 2 \cdot t_{f}) \cdot t_{w}^3) \cdot (h - t_{f})^2}{48}
  • General formula, independent of standards
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

yzbhtftw

Formula and quantities

SymbolNameUnitNote
h\displaystyle hAlturammh\displaystyle h > 0
b\displaystyle bLargurammb\displaystyle b > 0
tw\displaystyle t_{w}Espessura da almammtw\displaystyle t_{w} > 0
tf\displaystyle t_{f}Espessura do banzommtf\displaystyle t_{f} > 0
Iw\displaystyle I_{w}Constante de empenamentocm⁶Result

Valid if2⋅tf<h\displaystyle 2 \cdot t_{f} < htw<b\displaystyle t_{w} < b

Exemplo resolvido

h\displaystyle h = 200 mm · b\displaystyle b = 100 mm · tw\displaystyle t_{w} = 6 mm · tf\displaystyle t_{f} = 10 mm

Iw\displaystyle I_{w} = 15.070,9 cm⁶ · Source: cálculo manual

Scope and standard

Seção I duplamente simétrica.

Result
Iw\displaystyle I_{w} in cm⁶

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Iw\displaystyle I_{w} = 15.070,9 cm⁶= ((2 · (10 mm) · (100 mm)³ + ((200 mm) - 2 · (10 mm)) · (6 mm)³) / 12) · ((200 mm) - (10 mm))² / 4

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

A busca começa em Seções transversais › Seções abertas de paredes delgadas.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.