Fator de redução χLT para flambagem lateral com torção: χLT = min(1,0 / (ΦLT + √(ΦLT² - λ̄LT²)); 1,0).

χLT=min⁡(1ΦLT+ΦLT2−λˉLT2;  1.0)\displaystyle \chi_{\mathrm{LT}} = \min\left(\frac{1}{\Phi_{\mathrm{LT}} + \sqrt{\Phi_{\mathrm{LT}}^2 - \bar{\lambda}_{\mathrm{LT}}^2}};\; 1.0\right)

Call in Calculate modechi_lt_ec3(Phi_LT; lambda_bar_LT)

Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

λLT

Formula and quantities

SymbolNameUnitNote
ΦLT\displaystyle \Phi_{\mathrm{LT}}Parâmetro da curva de flambagem lateral com torção–
λˉLT\displaystyle \bar{\lambda}_{\mathrm{LT}}Esbeltez adimensional para flambagem lateral com torção (LTB)–
χLT\displaystyle \chi_{\mathrm{LT}}Fator de redução para flambagem lateral com torção (LTB)–Result

Exemplo resolvido

ΦLT\displaystyle \Phi_{\mathrm{LT}} = 1,0908 · λˉLT\displaystyle \bar{\lambda}_{\mathrm{LT}} = 0,9607

χLT\displaystyle \chi_{\mathrm{LT}} = 0,622 · Source: EN 1993-1-1:2005 Eq. (6.56)

Scope and standard

Flambagem lateral com torção conforme EN 1993-1-1, item 6.3.2.2.

Standard
EN 1993-1-1:2005, item 6.3.2.2 (1), Eq. (6.56)
Result
χLT\displaystyle \chi_{\mathrm{LT}} (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

χLT\displaystyle \chi_{\mathrm{LT}} = 0,622113= min(1.0 / (1,0908 + sqrt(1,0908² - 0,9607²)); 1.0)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

A busca começa em Dimensionamento › Aço.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.