Sway imperfection
Determines phi = phi0 alpha_h alpha_m from the height of the structure and the number of columns in the row, the top displacement delta0, and the equivalent horizontal force H = phi N_Ed.
Privacy settings
We use Microsoft Clarity to understand how CALC is used — only if you agree. Necessary cookies keep the app working (sign-in, security, free-quota enforcement) and are always active.

SKL-000147 · Skill
EN 1993-1-1:2005+AC:2009+A1:2014, 5.3.2(3), 5.3.2(4)B, 5.3.2(7), Table 5.1, Table 6.2DIN EN 1993-1-1/NA:2022-10, NDP 5.3.2(3) with Table NA.2Enter the height of the structure, the number of columns in the row, the axial force, the section, and the plane considered. Mia determines the sway imperfection, the initial bow e0, and the equivalent forces to EN 1993-1-1, 5.3.2, and draws both load figures for your frame model.
Mia guides you step by stepShe guides you through the inputs and explains the results.
Determine the sway and bow imperfections of a HEB 240 column in S355 to EN 1993-1-1:2005+AC:2009 with DIN EN 1993-1-1/NA:2022-10, height of the structure h = 6 m, four columns in the row, NEd = 850 kN, buckling about y-y, elastic cross-section utilization, bow from Table NA.2.
All values are deterministic for the stated inputs; alpha_h = 0.816 and alpha_m = 0.791 to 5.3.2(3).
These templates prefill the form with typical inputs. They are not calculated results; the calculation runs in CALC.
Determines phi = phi0 alpha_h alpha_m from the height of the structure and the number of columns in the row, the top displacement delta0, and the equivalent horizontal force H = phi N_Ed.
Selects the buckling curve from Table 6.2 and the bow e0/L from Table 5.1 or, with the German NA, from Table NA.2, including the factor W_pl/W_el for plastic cross-section utilization.
Converts the bow into the uniform load q = 8 N e0 / L² and the end forces F = 4 N e0 / L of Figure 5.4.
With the storey totals H_Ed and V_Ed, checks whether the sway may be neglected to 5.3.2(4)B.
Normative basis
The checks follow these standards. Nationally determined parameters come from the National Annex selected in the form.
Edition used: DIN EN 1993-1-1:2010-12 (EN 1993-1-1:2005 + AC:2009) + DIN EN 1993-1-1/A1:2014-07
| Country | National Annex | Factors | Source |
|---|---|---|---|
| DE | DIN EN 1993-1-1/NA:2022-10WithdrawnNewer edition: DIN EN 1993-1-1/NA:2026-04 | DIN Media | |
| EN | Recommended valuesEN 1993-1-1:2005 + AC:2009 + A1:2014 | – |
Status checked on
Frequently asked questions
The height of the structure, the number of columns in the row, the axial force, the section, the steel grade, and the plane considered. The section values come from the CALC library, and the buckling curve follows from Table 6.2.
They are the totals of the horizontal and vertical design loads of the whole storey, that is all columns of the row. With both values Mia checks whether HEd ≥ 0.15 VEd, in which case the sway may be neglected to 5.3.2(4)B. Without them the sway is applied.
Table 5.1 gives e0/L for an elastic or a plastic column. The German NA allows Table NA.2 for an elastic global analysis with the linear interaction Eq. (6.2); for plastic cross-section utilization its value is multiplied by Wpl/W_el.
Apply H at the top of the column and the opposite force at its base. Apply q uniformly along the member and the forces F at both member ends, opposite to q, as shown in Figure 5.4. Consider one direction at a time.
No. It prepares the imperfections and equivalent loads for the global analysis. For the buckling verification use the steel column skill.
Start with the example and adapt it to your structural system.
New calculation