Sawn lumber and glulam
Douglas Fir-Larch, Hem-Fir, Spruce-Pine-Fir and Southern Pine dimension lumber and Beams and Stringers, and glulam stress classes from the NDS Supplement 2024.
Privacy settings
We use Microsoft Clarity to understand how CALC is used — only if you agree. Necessary cookies keep the app working (sign-in, security, free-quota enforcement) and are always active.

SKL-000149 · Skill
ANSI/AWC NDS-2024NDS Supplement 2024ASCE/SEI 7-22Describe the span, the member (sawn lumber or glulam), species and grade, the loads and how the edges are braced. Mia applies the NDS adjustment factors, checks bending with beam stability, shear, bearing and deflection in ASD or LRFD, and names the governing check.
Mia guides you step by stepShe guides you through the inputs and explains the results.
Check 2x10 Douglas Fir-Larch No.2 floor joists at 16 in. on center, simply supported over 14 ft, with 15 psf dead load plus self-weight and 40 psf live load, sheathing on the top edge, 3-1/2 in. bearing, to NDS 2024 ASD with L/360 live and L/240 total deflection limits.
All values are deterministic for the stated inputs and reproduced by the skill's calculation code with the 2024 NDS Supplement Table 4A values for Douglas Fir-Larch No.2 (Fb = 900 psi, Fv = 180 psi, Fc⊥ = 625 psi, E = 1.6 x 10^6 psi).
These templates prefill the form with typical inputs. They are not calculated results; the calculation runs in CALC.
Douglas Fir-Larch, Hem-Fir, Spruce-Pine-Fir and Southern Pine dimension lumber and Beams and Stringers, and glulam stress classes from the NDS Supplement 2024.
C_D or lambda, C_M, C_t, C_F, C_r, C_i and C_V applied per NDS Tables 4.3.1 and 5.3.1, each named with its value.
Effective length from Table 3.3.3, R_B and F_bE for the compression edge, including net uplift with the bottom edge in compression.
All ASCE 7-22 combinations of D, L, Lr, S and W, each with its load duration factor or time effect factor, and the governing one named.
Normative basis
The checks follow these standards. Nationally determined parameters come from the National Annex selected in the form.
Edition used: NDS 2024
Status checked on
Edition used: 2024
Status checked on
Edition used: ASCE 7-22
Status checked on
Frequently asked questions
ANSI/AWC NDS 2024 with the 2024 NDS Supplement design values, and the load combinations of ASCE/SEI 7-22 for ASD and LRFD.
Each combination uses CD of its shortest-duration load (Table 2.3.2), for example 1.0 for D + L, 1.15 for D + 0.7S and 1.6 with wind. All combinations are checked, so D alone with CD = 0.9 can govern. In LRFD the time effect factor lambda of Table N3 takes its place.
When the compression edge is braced continuously, for example by sheathing fastened to it (3.3.3.3), or when the depth does not exceed the width. Otherwise Mia computes CL from the effective length of Table 3.3.3 for the edge in compression.
Enter W as a negative value. In 0.6D + 0.6W (ASD) or 0.9D + 1.0W (LRFD) the moment reverses, the bottom edge is in compression and CL uses the bracing of the bottom edge.
Total deflection = Kcr x the dead-load deflection + the live, roof live or snow load deflection (NDS 3.5.2), with Kcr = 1.5 for seasoned lumber and glulam in dry service and 2.0 for wet service.
Start with the example and adapt it to your structural system.
New calculation