Tasarım · Beton

Burulma boyuna donatısı Asl

  • Tür: Özellik
  • Versiyon 1
  • 10.11.2026 tarihinde gözden geçirildi

EN 1992-1-1 Denklem (6.28)'e göre burulma için gerekli toplam boyuna donatı alanı.

Asl=TEd⋅uk⋅cot⁡θ2⋅Ak⋅fyd\displaystyle A_{sl} = \frac{T_{\mathrm{Ed}} \cdot u_{k} \cdot \cot \theta}{2 \cdot A_{k} \cdot f_{yd}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Asluk

Formula and quantities

SymbolNameUnitNote
TEd\displaystyle T_{\mathrm{Ed}}Hesaplanan burulma momentiNm
uk\displaystyle u_{k}Ak çevresimm
cot⁡θ\displaystyle \cot \thetaBasma çubuğu açısının kotanjantı–
Ak\displaystyle A_{k}Orta eksenler tarafından çevrelenen alanmm²
fyd\displaystyle f_{yd}Boyuna donatının hesaplanan akma dayanımıN/mm²
Asl\displaystyle A_{sl}Gerekli burulma boyuna donatısımm²Result

Çözümlü örnek

TEd\displaystyle T_{\mathrm{Ed}} = 30.000 Nm · uk\displaystyle u_{k} = 1.400 mm · cot⁡θ\displaystyle \cot \theta = 1,5 · Ak\displaystyle A_{k} = 120.000 mm² · fyd\displaystyle f_{yd} = 435 N/mm²

Asl\displaystyle A_{sl} = 603,45 mm² · Source: EN 1992-1-1:2004 Denk. (6.28)

Scope and standard

EN 1992-1-1'e göre burulmaya maruz betonarme kirişler.

Standard
EN 1992-1-1:2004, madde 6.3.2 (3), Denk. (6.28)
Result
Asl\displaystyle A_{sl} in mm²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Asl\displaystyle A_{sl} = 603,448 mm²= ((30.000 Nm) · (1.400 mm) · 1,5) / (2 · (120.000 mm²) · (435 N/mm²))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

Arama Tasarım › Beton içinde başlıyor.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.