设计 · 混凝土
混凝土抗折强度 fr (ACI 318)
根据 ACI 318-19 第 19.2.3.1 节(SI 单位)用于挠度和开裂弯矩计算的混凝土抗折强度:fr = 0.62 · λ · √(fc / MPa) · MPa。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 轻骨料混凝土修正系数(普通混凝土取 1.0) | 1 | ||
| 混凝土规定抗压强度 | N/m² | ||
| 抗折强度 | N/m² | Result |
实例
= 1 1 · = 28,000,000 N/m²
= 3,280,700 N/m²
Standard and source
- Standard
- ACI 318-19
- Result
- in MPa
Reference to clause and equation, no standard text. The description is written in our own words.