设计 · 玻璃
预应力玻璃抗弯强度设计值
根据 EN 16612 计算的钢化或半钢化玻璃抗弯强度设计值 fg,d:fg,d = (kmod · ksp · fg,k) / γM,A + (kv · (fb,k - fg,k)) / γM,v。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 荷载持续时间修正系数 | 1 | ||
| 表面状态系数 | 1 | ||
| 退火玻璃抗弯强度标准值 | N/m² | ||
| 退火玻璃分项系数 | 1 | ||
| 钢化工艺系数 | 1 | ||
| 预应力玻璃抗弯强度标准值 | N/m² | ||
| 预应力分量分项系数 | 1 | ||
| 设计弯曲强度 | N/m² | Result |
实例
= 0.72 · = 1 · = 45,000,000 N/m² · = 1.8 · = 1 · = 120,000,000 N/m² · = 1.2
= 80,500,000 N/m²
Standard and source
- Standard
- EN 16612:2019
- Result
- in MPa
Reference to clause and equation, no standard text. The description is written in our own words.