设计 · 玻璃

预应力玻璃抗弯强度设计值

  • 类型:承载力
  • 版本1
  • 2026/11/13已审核

根据 EN 16612 计算的钢化或半钢化玻璃抗弯强度设计值 fg,d:fg,d = (kmod · ksp · fg,k) / γM,A + (kv · (fb,k - fg,k)) / γM,v。

fg,d=(kmod⋅ksp⋅fg,k)/γM,A+(kv⋅(fb,k−fg,k))/γM,v\displaystyle f_{g,\mathrm{d}} = (k_{mod} \cdot k_{sp} \cdot f_{g,k}) / \gamma _{M,\mathrm{A}} + (k_{v} \cdot (f_{\mathrm{b},k} - f_{g,k})) / \gamma _{M,v}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

fgd

Formula and quantities

SymbolNameUnitNote
kmod\displaystyle k_{mod}荷载持续时间修正系数1
ksp\displaystyle k_{sp}表面状态系数1
fg,k\displaystyle f_{g,k}退火玻璃抗弯强度标准值N/m²
γM,A\displaystyle \gamma_{M,\mathrm{A}}退火玻璃分项系数1
kv\displaystyle k_{v}钢化工艺系数1
fb,k\displaystyle f_{\mathrm{b},k}预应力玻璃抗弯强度标准值N/m²
γM,v\displaystyle \gamma_{M,v}预应力分量分项系数1
fg,d\displaystyle f_{g,\mathrm{d}}设计弯曲强度N/m²Result

实例

kmod\displaystyle k_{mod} = 0.72 · ksp\displaystyle k_{sp} = 1 · fg,k\displaystyle f_{g,k} = 45,000,000 N/m² · γM,A\displaystyle \gamma_{M,\mathrm{A}} = 1.8 · kv\displaystyle k_{v} = 1 · fb,k\displaystyle f_{\mathrm{b},k} = 120,000,000 N/m² · γM,v\displaystyle \gamma_{M,v} = 1.2

fg,d\displaystyle f_{g,\mathrm{d}} = 80,500,000 N/m²

Standard and source

Result
fg,d\displaystyle f_{g,\mathrm{d}} in MPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
fg,d\displaystyle f_{g,\mathrm{d}} = 80,500,000 N/m²= ((0.72 1) · (1 1) · (45,000,000 N/m²)) / (1.8 1) + ((1 1) · ((120,000,000 N/m²) - (45,000,000 N/m²))) / (1.2 1)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

检索将在 设计 › 玻璃 开始。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.