局部荷载作用下砌体墙的竖向承载力设计值:NRdc = β · Ab · fd。

NRdc=β⋅Ab⋅fd\displaystyle N_{Rdc} = \beta \cdot A_{\mathrm{b}} \cdot f_{\mathrm{d}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

NRdcAbfdβ

Formula and quantities

SymbolNameUnitNote
β\displaystyle β局部受压提高系数–β\displaystyle β ≥ 1, ≤ 1.5
Ab\displaystyle A_{\mathrm{b}}局部受压面积mm²Ab\displaystyle A_{\mathrm{b}} > 0
fd\displaystyle f_{\mathrm{d}}砌体抗压强度设计值N/mm²fd\displaystyle f_{\mathrm{d}} > 0
NRdc\displaystyle N_{Rdc}局部受压承载力设计值kNResult

实例

β\displaystyle β = 1.35 · Ab\displaystyle A_{\mathrm{b}} = 48,000 mm² · fd\displaystyle f_{\mathrm{d}} = 3 N/mm²

NRdc\displaystyle N_{Rdc} = 194.4 kN · Source: 手算

Scope and standard

EN 1996-1-1 第 6.1.3 条。

Standard
EN 1996-1-1-2005-a1:2012,第6.1.3条,式(6.9)
Result
NRdc\displaystyle N_{Rdc} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
NRdc\displaystyle N_{Rdc} = 194.4 kN= 1.35 · (48,000 mm²) · (3 N/mm²)