Design · Masonry
Design resistance to concentrated loads on masonry
Design vertical resistance of a masonry wall under a concentrated load: NRdc = β · Ab · fd.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Concentrated load enhancement factor | – | ≥ 1, ≤ 1.5 | |
| Loaded bearing area | mm² | > 0 | |
| Design compressive strength of masonry | N/mm² | > 0 | |
| Design concentrated load resistance | kN | Result |
Worked example
= 1.35 · = 48,000 mm² · = 3 N/mm²
= 194.4 kN · Source: hand calculation
Scope and standard
EN 1996-1-1, clause 6.1.3.
- Standard
- EN 1996-1-1-2005-a1:2012, clause 6.1.3, Eq. (6.9)
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.