设计 · 砌体
砌体墙初始偶然偏心距
考虑全墙高施工偏差的初始偏心距:einit = hef / 450。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 墙体计算高度 | mm | > 0 | |
| 初始偏心距 | mm | Result |
实例
= 2,700 mm
= 6 mm · Source: 手算
Scope and standard
EN 1996-1-1 第 5.5.1.1 条。
- Standard
- EN 1996-1-1-2005-a1:2012,第5.5.1.1条,式(5.2)
- Result
- in mm
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
检索将在 设计 › 砌体 开始。
Miaknows the formula catalog and asks for what is missing.