设计 · 砌体
砌体墙顶部或底部设计偏心距
墙体顶部或底部综合荷载弯矩、水平作用和初始偏心距的设计偏心距,不小于 0.05 · t。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 墙体顶部或底部设计弯矩 | N | ||
| 墙体顶部或底部竖向荷载设计值 | kN/m | > 0 | |
| 水平荷载产生的偏心距 | mm | ≥ 0 | |
| 初始偶然偏心距 | mm | ≥ 0 | |
| 墙厚 | mm | > 0 | |
| 端部设计偏心距 | mm | Result |
实例
= 4,000 N · = 200 kN/m · = 0 mm · = 6 mm · = 240 mm
= 26 mm · Source: 手算
Scope and standard
EN 1996-1-1 第 6.1.2.2 条。
- Standard
- EN 1996-1-1-2005-a1:2012,第6.1.2.2条,式(6.5)
- Result
- in mm
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
检索将在 设计 › 砌体 开始。
Miaknows the formula catalog and asks for what is missing.