设计 · 连接件

柱脚底板下混凝土承压强度 fjd

  • 类型:属性
  • 版本1
  • 2026/11/13已审核

钢柱底板下混凝土或灌浆层的设计承压强度:fjd = βj · kj · fcd。

fjd=βj⋅kj⋅fcd\displaystyle f_{jd} = \beta _{j} \cdot k_{j} \cdot f_{cd}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

fjdfcdβj

Formula and quantities

SymbolNameUnitNote
βj\displaystyle \beta_{j}基础接缝材料系数(通常取 2/3)1
kj\displaystyle k_{j}承压面积集中系数1
fcd\displaystyle f_{cd}基础混凝土设计抗压强度N/m²
fjd\displaystyle f_{jd}设计混凝土承压强度N/m²Result

实例

βj\displaystyle \beta_{j} = 0.667 · kj\displaystyle k_{j} = 1.5 · fcd\displaystyle f_{cd} = 16,670,000 N/m²

fjd\displaystyle f_{jd} = 16,680,000 N/m²

Standard and source

Result
fjd\displaystyle f_{jd} in MPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
fjd\displaystyle f_{jd} = 16,678,300 N/m²= (0.667 1) · (1.5 1) · (16,670,000 N/m²)