Design · Connections

Base plate concrete bearing strength fjd

  • Type: Property
  • Version 1
  • reviewed on 11/13/2026

Design bearing strength of the concrete or grout joint beneath a steel column base plate: fjd = βj · kj · fcd.

fjd=βj⋅kj⋅fcd\displaystyle f_{jd} = \beta _{j} \cdot k_{j} \cdot f_{cd}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

fjdfcdβj

Formula and quantities

SymbolNameUnitNote
βj\displaystyle \beta_{j}Foundation joint material coefficient (typically 2/3)1
kj\displaystyle k_{j}Concentration factor for bearing area1
fcd\displaystyle f_{cd}Design compressive strength of foundation concreteN/m²
fjd\displaystyle f_{jd}Design concrete bearing strengthN/m²Result

Worked example

βj\displaystyle \beta_{j} = 0.667 · kj\displaystyle k_{j} = 1.5 · fcd\displaystyle f_{cd} = 16,670,000 N/m²

fjd\displaystyle f_{jd} = 16,680,000 N/m²

Standard and source

Result
fjd\displaystyle f_{jd} in MPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
fjd\displaystyle f_{jd} = 16,678,300 N/m²= (0.667 1) · (1.5 1) · (16,670,000 N/m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Connections.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.