设计 · 混凝土
CTT 节点抗压强度设计值 σRd,max
多向拉杆压-拉节点最大设计压应力,按 EN 1992-1-1 式 (6.62): σRd,max = 0.75 · nu' · fcd。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 强度折减系数 (1 - f_ck / 250) | 1 | ||
| 混凝土设计抗压强度 | N/m² | ||
| CTT 节点抗压强度设计值 | N/m² | Result |
实例
= 0.88 1 · = 17,000,000 N/m²
= 11,220,000 N/m² · Source: EN 1992-1-1:2004 式 (6.62)
Scope and standard
按 EN 1992-1-1 拉压杆模型中的 CTT (压-拉-拉) 节点。
- Standard
- EN 1992-1-1:2004,第6.5.4 (5)条,式(6.62)
- Result
- in MPa
Reference to clause and equation, no standard text. The description is written in our own words.