设计 · 混凝土

冲切加固的有效强度 fywd,ef

  • 类型:属性
  • 版本1
  • 2026/11/10已审核

根据 EN 1992-1-1 第6.4.5 (1)条的冲切剪切加固设计有效强度。

fywd,ef=250 MPa+0.25⋅d⋅(1 MPa1 mm)\displaystyle f_{ywd,\mathrm{ef}} = 250\,\text{MPa} + 0.25 \cdot d \cdot \left(\frac{1\,\text{MPa}}{1\,\text{mm}}\right)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

d

Formula and quantities

SymbolNameUnitNote
d\displaystyle d楼板有效高度mm
fywd,ef\displaystyle f_{ywd,\mathrm{ef}}冲切加固的有效强度N/mm²Result

实例

d\displaystyle d = 200 mm

fywd,ef\displaystyle f_{ywd,\mathrm{ef}} = 300 N/mm² · Source: EN 1992-1-1:2004 cl. 6.4.5 (1)

Scope and standard

根据 EN 1992-1-1 的楼板冲切剪切加固。

Standard
EN 1992-1-1:2004,第6.4.5 (1)条,式(6.52)
Result
fywd,ef\displaystyle f_{ywd,\mathrm{ef}} in N/mm²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
fywd,ef\displaystyle f_{ywd,\mathrm{ef}} = 300 N/mm²= 250 [MPa] + 0.25 · ((200 mm) / 1 [mm]) · 1 [MPa]