岩土工程 · 土压力
挡土墙上的静水压力合力 Ew (EN 1997-1)
根据 EN 1997-1 第 9.6 条浸水高度 Hw 上单位墙长的水平静水压力合力:Ew = 0.5 · γw · Hw²。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 水的重度(通常取 10 kN/m^3) | kN/m³ | ||
| 墙底以上地下水位高度 | m | ||
| 单位长度静水压力合力 | kN/m | Result |
实例
= 10 kN/m³ · = 3 m
= 45 kN/m
Standard and source
- Standard
- EN 1997-1:2004
- Result
- in kN/m