FAQ-000058 · Calculation & Verification

Can Mia help if my RFEM model does not calculate?

Mia reads the error messages from RFEM, explains the cause, and suggests a fix. She changes the model only after you agree.

Dlubal CALC · Updated:

The short answer

Yes. If RFEM 6 is connected and the calculation stops, Mia reads the errors and warnings from RFEM. She explains in plain language what is behind them and suggests a concrete fix. Mia can adjust settings such as the static analysis settings at your request. She does not change your model on her own just to make the calculation run. Responsibility for the model and the results remains with you.

Requirement: RFEM 6 is connected to CALC

Mia can read the error messages only when CALC is connected to RFEM 6. For that, RFEM 6 and the Dlubal-Connector must run on the same Windows computer. FAQ-000001 “Connect CALC to RFEM 6, RSTAB 9, or RSECTION” explains how to set up the connection. This works the same way with RSTAB 9.

Without a connection, Mia can still help: Copy the error message from RFEM into the chat, and Mia explains what it may mean. She does not see your model in that case.

How Mia finds the cause

Activate the affected model in RFEM and ask Mia, for example: “Calculate the model and explain why the calculation stops.”

Mia reads the errors and warnings of the calculation and puts them into context. Typical causes are missing or insufficient supports, a mechanism caused by too many hinges, loads in a direction without a support, or missing load cases and analysis settings.

For each cause she names a possible fix, such as an additional support, bracing, or a changed hinge definition.

Can Mia change solver settings?

Yes, at your request. Tell Mia exactly which setting should change and how.

Mia does not change such settings silently. The same applies to load cases, combinations, activated add-ons, and load cases that you deliberately excluded from the calculation. She names what blocks the calculation and asks you.

Changes to the model go through the approval that you set in the settings. CALC cannot undo them, so save a model state beforehand.

What you should check yourself

A calculation that runs through is not yet a correct model. A changed setting can also merely hide an instability. Check deformations, support reactions, and the sum of the loads for plausibility.

Mia's explanations and suggested fixes help you find the error. You decide whether a fix suits your structure. As with any structural analysis software, responsibility for the model and the results remains with you.

If your model already has results, Mia asks before calculating again, because a new calculation replaces the existing results.

While a dialog is open in RFEM, Mia cannot access the model.