Design tension resistance of a bolt in an aluminium connection: Ft,Rd = k2 · fub · As / γM2.

Ft,Rd=k2⋅fub⋅As/γM2\displaystyle F_{t,\mathrm{Rd}} = k_{2} \cdot f_{ub} \cdot A_{s} / \gamma _{\mathrm{M2}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

FtRdAsfub

Formula and quantities

SymbolNameUnitNote
k2\displaystyle k_{2}Bolt head factor (0.9 for standard, 0.63 for countersunk)1
fub\displaystyle f_{ub}Ultimate tensile strength of boltN/m²
As\displaystyle A_{s}Tensile stress area of boltmm²
γM2\displaystyle \gamma_{\mathrm{M2}}Partial factor for bolted connections1
Ft,Rd\displaystyle F_{t,\mathrm{Rd}}Design tension resistance of boltkNResult

Worked example

k2\displaystyle k_{2} = 0.9 · fub\displaystyle f_{ub} = 800,000,000 N/m² · As\displaystyle A_{s} = 157 mm² · γM2\displaystyle \gamma_{\mathrm{M2}} = 1.25

Ft,Rd\displaystyle F_{t,\mathrm{Rd}} = 90.43 kN

Standard and source

Result
Ft,Rd\displaystyle F_{t,\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Ft,Rd\displaystyle F_{t,\mathrm{Rd}} = 90.432 kN= (0.9 1) · (800,000,000 N/m²) · (157 mm²) / (1.25 1)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Aluminium.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.