Design · Aluminium

Design ultimate tension resistance Nu,Rd

  • Type: Resistance
  • Version 1
  • reviewed on 11/13/2026

Design ultimate resistance of the net cross-section at bolt holes in tension: Nu,Rd = 0.9 · Anet · fu / γM2.

Nu,Rd=0.9⋅Anet⋅fu/γM2\displaystyle N_{u,\mathrm{Rd}} = 0.9 \cdot A_{net} \cdot f_{u} / \gamma _{\mathrm{M2}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
Anet\displaystyle A_{net}Net cross-sectional area at bolt holescm²
fu\displaystyle f_{u}Characteristic ultimate tensile strengthN/m²
γM2\displaystyle \gamma_{\mathrm{M2}}Partial factor for resistance of net sections to fracture1
Nu,Rd\displaystyle N_{u,\mathrm{Rd}}Design ultimate tension resistancekNResult

Worked example

Anet\displaystyle A_{net} = 20 cm² · fu\displaystyle f_{u} = 310,000,000 N/m² · γM2\displaystyle \gamma_{\mathrm{M2}} = 1.25

Nu,Rd\displaystyle N_{u,\mathrm{Rd}} = 446.4 kN

Standard and source

Result
Nu,Rd\displaystyle N_{u,\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Nu,Rd\displaystyle N_{u,\mathrm{Rd}} = 446.4 kN= 0.9 · (20 cm²) · (310,000,000 N/m²) / (1.25 1)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Aluminium.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.