Design · Connections

Concrete pry-out shear resistance VRk,cp (EN 1992-4)

  • Type: Property
  • Version 1
  • reviewed on 11/25/2026

Characteristic concrete pry-out failure resistance under shear loading according to EN 1992-4 Clause 7.2.2.4 Eq. (7.39a): VRk,cp = k8 · NRk,c.

VRk,cp=k8⋅NRk,c\displaystyle V_{Rk,cp} = k_{8} \cdot N_{Rk,\mathrm{c}}
  • EN 1992-4:2018
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

VRkcpNRkc

Formula and quantities

SymbolNameUnitNote
k8\displaystyle k_{8}Pry-out factor (1.0 for h_ef < 60 mm, 2.0 for h_ef >= 60 mm)1
NRk,c\displaystyle N_{Rk,\mathrm{c}}Characteristic concrete cone resistancekN
VRk,cp\displaystyle V_{Rk,cp}Characteristic concrete pry-out resistancekNResult

Worked example

k8\displaystyle k_{8} = 2 · NRk,c\displaystyle N_{Rk,\mathrm{c}} = 38.5 kN

VRk,cp\displaystyle V_{Rk,cp} = 77 kN

Standard and source

Standard
EN 1992-4:2018
Result
VRk,cp\displaystyle V_{Rk,cp} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
VRk,cp\displaystyle V_{Rk,cp} = 77 kN= (2 1) · (38.5 kN)