Cross-sections · Built-up sections

Longitudinal shear flow at built-up section interface

  • Type: Property
  • Version 1
  • reviewed on 11/15/2026

Longitudinal shear flow per unit length between components of a built-up beam: vL = (VEd · Sy) / Iy.

vL=VEd⋅SyIy\displaystyle v_{L} = \frac{V_{\mathrm{Ed}} \cdot S_{y}}{I_{y}}
  • General formula, independent of standards
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
VEd\displaystyle V_{\mathrm{Ed}}Design shear forceN
Sy\displaystyle S_{y}First moment of area of separated partm³
Iy\displaystyle I_{y}Total second moment of aream⁴
vL\displaystyle v_{L}Longitudinal shear flowN/mResult

Worked example

VEd\displaystyle V_{\mathrm{Ed}} = 100,000 N · Sy\displaystyle S_{y} = 0.0004 m³ · Iy\displaystyle I_{y} = 0.0002 m⁴

vL\displaystyle v_{L} = 200,000 N/m

Standard and source

Result
vL\displaystyle v_{L} in N/m

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
vL\displaystyle v_{L} = 200,000 N/m= ((100,000 N) · (0.0004 m³)) / (0.0002 m⁴)