Cross-sections · Built-up sections
Built-up column critical buckling load with shear stiffness
Elastic critical buckling load of a built-up compression member accounting for finite shear stiffness Sv: Ncr = (π² · E · Ieff) / (L² · (1 + (π² · E · Ieff) / (L² · Sv))).
- General formula, independent of standards
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Young's modulus | N/m² | ||
| Effective second moment of area | m⁴ | ||
| Buckling length | m | ||
| Shear stiffness of lacing or battens | N | ||
| Elastic critical buckling load | N | Result |
Worked example
= 210,000,000,000 N/m² · = 0.0001 m⁴ · = 6 m · = 20,000,000 N
= 4,475,520 N
Standard and source
- Result
- in N
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my dimensionsenter values, check the result
- Compare with a catalog sectionformula value and table value
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Cross-sections › Built-up sections.
Miaknows the formula catalog and asks for what is missing.