Design · Composite
Plastic neutral axis depth in concrete flange xpl
Depth of the plastic neutral axis measured from the top of the concrete slab when Npl,a <= Ncf: xpl = Npl,a / (0.85 · fcd · beff).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Plastic axial resistance of steel section | kN | ||
| Design value of concrete compressive strength | N/m² | ||
| Total effective width of concrete flange | mm | ||
| Depth of plastic neutral axis in concrete flange | mm | Result |
Worked example
= 2,580.85 kN · = 20,000,000 N/m² · = 2,000 mm
= 75.91 mm
Standard and source
- Standard
- EN 1994-1-1:2004
- Result
- in mm
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my dimensionsenter values, check the result
- Compare with a catalog sectionformula value and table value
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Composite.
Miaknows the formula catalog and asks for what is missing.