Design · Composite

Number of studs for full shear connection nf

  • Type: Property
  • Version 1
  • reviewed on 11/13/2026

Required number of shear connectors over the critical length for full shear connection: nf = min(Ncf, Npl,a) / PRd.

nf=min(Ncf,Npl,a)/PRd\displaystyle n_{f} = min(N_{cf}, N_{\mathrm{pl},a}) / P_{\mathrm{Rd}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

PRdnf

Formula and quantities

SymbolNameUnitNote
Ncf\displaystyle N_{cf}Plastic compressive resistance of concrete flangekN
Npl,a\displaystyle N_{\mathrm{pl},a}Plastic axial resistance of steel sectionkN
PRd\displaystyle P_{\mathrm{Rd}}Design shear resistance of one shear connectorkN
nf\displaystyle n_{f}Required number of shear connectors1Result

Worked example

Ncf\displaystyle N_{cf} = 4,080 kN · Npl,a\displaystyle N_{\mathrm{pl},a} = 2,580.85 kN · PRd\displaystyle P_{\mathrm{Rd}} = 81.66 kN

nf\displaystyle n_{f} = 31.6

Standard and source

Result
nf\displaystyle n_{f} in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
nf\displaystyle n_{f} = 31.6048 1= min((4,080 kN); (2,580.85 kN)) / (81.66 kN)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Composite.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.