Design · Composite
Bending resistance with partial shear connection MRd
Conservative linear interpolation of bending moment resistance for ductile shear connectors: MRd = Mpl,a,Rd + (Mpl,Rd - Mpl,a,Rd) · eta.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Plastic bending resistance of steel section alone | kNm | ||
| Plastic bending resistance with full shear connection | kNm | ||
| Degree of shear connection | 1 | ||
| Design bending resistance with partial shear connection | kNm | Result |
Worked example
= 360 kNm · = 680 kNm · = 0.65
= 568 kNm
Standard and source
- Standard
- EN 1994-1-1:2004
- Result
- in kNm
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my memberwith Mia in CALC
- Compare with RFEM/RSTAB resultshand calculation versus model
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Composite.
Miaknows the formula catalog and asks for what is missing.