Design · Composite
Headed stud shear resistance (steel failure) PRd,1
Design shear resistance of a headed stud governed by shear failure of the stud shank: PRd,1 = (0.8 · fu · π · d² / 4) / γV.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Specified ultimate tensile strength of stud steel | N/m² | ||
| Diameter of headed stud shank | mm | ||
| Partial factor for shear connection | 1 | ||
| Stud shear resistance (steel failure) | kN | Result |
Worked example
= 450,000,000 N/m² · = 19 mm · = 1.25
= 81.66 kN
Standard and source
- Standard
- EN 1994-1-1:2004
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my memberwith Mia in CALC
- Compare with RFEM/RSTAB resultshand calculation versus model
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Composite.
Miaknows the formula catalog and asks for what is missing.