Design · Concrete
Second order nominal deflection e2
Nominal second order deflection for slender columns to EN 1992-1-1 Eq. (5.33): e2 = (1/r) · l0² / c.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Total nominal curvature | m⁻¹ | ||
| Effective buckling length of column | m | ||
| Curvature distribution factor (10 for constant curvature, pi^2 ~ 9.87 for sinusoidal) | 1 | ||
| Second order nominal deflection | m | Result |
Worked example
= 0.012 m⁻¹ · = 4 m · = 10 1
= 0.0192 m · Source: EN 1992-1-1:2004 Eq. (5.33)
Scope and standard
Slender reinforced concrete columns to EN 1992-1-1.
- Standard
- EN 1992-1-1:2004, clause 5.8.8.2 (3), Eq. (5.33)
- Result
- in mm
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my dimensionsenter values, check the result
- Compare with a catalog sectionformula value and table value
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Concrete.
Miaknows the formula catalog and asks for what is missing.